United States Argentina Australia Austria Belgium Canada Chile Colombia Costa Rica Dominican Republic France Germany Bangladesh/India Italy Kenya Mexico Netherlands Puerto Rico South Africa Sweden Switzerland Venezuela
BASIS International Ltd.
Home | Site Map | Contact Us | Partner Login  

 













BASIS Knowledge Base Article #00331

Title:

fserr=61, fserr=-161 when connecting to a datasource via the ODBC Driver

Description:

1. This error will occur when there are spaces in the config.tpm file after the equals sign (=)

DICTIONARY= /<kazoo,port=5150>/u/bbx/BBDICT/
DATA= /<kazoo,port=5150>/u/bbx/data/

2. This error can also occur if there isn't a leading / in the path to either the DICTIONARY of DATA


3. This error can also occur if the 'Network User ID' field in the datasource configuration Advanced section of the Windows ODBC Administrator is blank or incorrect.

4. This error can also occur if the syntax is incorrect in the DICTIONARY= line of the config.tpm.
DICTIONARY=/<kazoo,5150>u/bbx/BBDICT/


Resolution:

1. Remove the extra spaces.

2. Ensure there is a leading slash.

3. Enter a valid User ID in the field.

4. Ensure the syntax to use the Data Server is correct.

Last Modified: 08/28/1998
Product: BASIS ODBC Driver
Operating System: Windows
Error Number: 61
OS Error: 161